FadeStop™ Fluorescent Mounting Medium with DAPI #272

基因名:
货号:
272
应用:
fluorescence microscopy, flow cytometry, and chromosome staining

Information

Aliases:


Background:
FadeStop™ fluorescent mounting medium is specially formulated to prolong the intensity of the fluorescence used in immunocytochemical and immunohistochemical staining. Our products can keep the fluorescent dyes from photobleaching for at least four months if the slides are stored at -20°C.  Concentration of DAPI: 1.5 μg/mL


Application Information
Apply one drop (approximately 20 μL) of FadeStop™ fluorescent mounting medium onto the coverslip, slide, or chamber slide containing the specimen. The amount of the medium is determined by the size of the specimen. As a general rule, apply just enough to cover the specimen area under the coverslip.
Seal the coverslip with quick-dry nail polish to prevent leakage of the mounting medium. Apply four drops of nail polish to each side of the coverslip to secure the coverslip. Then, seal all the sides of the cove


Storage
Store bottles upright at 4°C in the dark


Size Price
25 mL ¥ 720.00
10 mL ¥ 360.00
Datasheet
MSDS

Note

Product Datasheet
For research use only

BETTER ROOTS BETTER FRUITS

FadeStop™ Fluorescent Mounting Medium with DAPI #272


Aliases


Background

FadeStop™ fluorescent mounting medium is specially formulated to prolong the intensity of the fluorescence used in immunocytochemical and immunohistochemical staining. Our products can keep the fluorescent dyes from photobleaching for at least four months if the slides are stored at -20°C. 
Concentration of DAPI: 1.5 μg/mL


Application Information

Apply one drop (approximately 20 μL) of FadeStop™ fluorescent mounting medium onto the coverslip, slide, or chamber slide containing the specimen. The amount of the medium is determined by the size of the specimen. As a general rule, apply just enough to cover the specimen area under the coverslip.
Seal the coverslip with quick-dry nail polish to prevent leakage of the mounting medium. Apply four drops of nail polish to each side of the coverslip to secure the coverslip. Then, seal all the sides of the cove


Immunogen


                                    


Isotype


                                    


Storage Buffer


                                    


Storage

Store bottles upright at 4°C in the dark


Recommended Dilutions


                                    


Protocols


                                

Antibody Validation

Material Safety Data Sheet (MSDS) for Antibody

I. Identification:

Catalog Number: 272

Product Name: FadeStop™ Fluorescent Mounting Medium with DAPI #272

Manufacturer & Supplier: Hefei SciBen Biotech Co., Ltd

Address:Building 6, 98 Jiulong Road, Hefei, Anhui 230601, China

Tel: 0551-63635518

Fax: 540.605.9771

E-mail:support@scibenbio.com

II. Composition/Information on Ingredients:

This product is composed of antibodies in aqueous buffer solution. According to 29

CFR1910.1200(d), hazardous ingredients at less than < 1% and carcinogens at less than < 0.1% are considered non-hazardous. Any hazardous or carcinogenic ingredients exceeding these criteria are listed below.

This product may contain the following hazardous ingredients.

Ingredient:glycerol

CAS#:56-81-5

Percent: 50%

III. Hazard Identification:

Emergency Overview of Hazardous ingredient:glycerol (CAS# 56-81-5)

Caution:Avoid contact and inhalation.

Target Organ: Kidneys.

NFPA Rating:

Health Rating: 1

Flammability Rating: 0

Reactivity Rating:0

IV. First Aid Measures:

Inhalation:If inhaled, remove to fresh air. If breathing is difficult, get medical attention.

Ingestion: If swallowed and person is conscious, rinse out mouth with water. Get medical attention.

Skin Exposure:In case of contact, wash skin with soap and water.

Eye Exposure:In case of contact with eyes, immediately flush eyes water for at least 5minutes. Get medical attention.

V. Fire Fighting Measures:

Flash Point: Data not available.

Autoignition Temperature: Data not available.

Fire Extinguishing Media:Water spray, dry chemical, foam, or carbon dioxide.

Firefighting:Wear protective clothing and self-contained breathing apparatus to prevent contact with skin and eyes.

VI. Accidental Release Measures:

Absorb liquid with an absorbent material. Transfer contaminated absorbent to a chemical waste container for disposal.

VII. Handling And Storage:

Avoid inhalation and contact with eyes and skin. Avoid prolonged or repeated exposure. Store at –20 °C in tightly closed container.


VIII. Exposure Controls/Personal Protection:

Engineering Controls: Maintain adequate ventilation, eye wash and quick-drench facilities

IX. Physical and Chemical Properties:

Physical State:Colorless liquid.

Odor:Odorless.

Boiling Point:Data not available.

Melting Point:Data not available.

Volatile Organic Compound:Data not available.

Solubility in water:Readily miscible in water.

X. Stability and Reactivity:

Stability:Stable.

Hazardous Decomposition:May form carbon dioxide and carbon monoxide.

Conditions to avoid:Strong oxidizing agents

XI. Toxicological Information:

May cause skin irritation.

May be toxic if absorbed through skin or ingested.

May cause eye irritation.

Target Organs: Kidneys

Prolonged exposure may cause nausea, headache, and vomiting.

XII. Ecological Information:

Data not available.

XIII. Disposal Considerations:

Dispose of in accordance with federal, state and local environmental regulations.

XIV. Transport Information:

D.O.T.: This substance is considered non-hazardous for transport.

IATA: This substance is considered non-hazardous for air transport.

XV. Regulatory Information:

EU Regulation/Classification/Labeling Information: Not available for this product.

Chemical Inventory Status:

SARA Listed Component: None.

TSCA Listed Component: None.

Canada (WHMIS): DSL No, NDSL No.

XVI. Other Information:

This product is sold only for research use by personnel familiar with chemicals and who are well trained in good laboratory habits, such as avoiding spills, keeping hands clean at all times and not rubbing eyes with hands while working in the laboratory. This product is sold only in microliter quantities for use in life sciences research. No other use is intended, and any other use may involve substantive hazards. The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide for experienced personnel. Hefei SciBen Biotech Co., Ltd shall not be held liable for any damage resulting from the handling of or from contact with the above product. The burden of safe use of this material rests entirely with the user.

Issuing Date: 8/16/2024 Version: 1.0